MIT Magnetic Beads Track Muscle Movement for Better Prosthetic Control
- MIT researchers track muscle length and velocity with tiny magnetic beads implanted in muscle, in a study published in Nature Sensors
- Three participants with below-knee amputations completed the validation, with signals read from up to 6 centimeters beneath the skin
- The beads are 3 millimeters across, about the size of a sesame seed, made of a neodymium, iron and boron alloy and coated with gold and parylene C
- Comparison experiments show the magnet-based approach offers more accurate and stable control than implanted and surface electrodes
Neuroprosthetic limbs use neural information from the muscles remaining after an amputation to guide the prosthetic limb. For decades, these devices have relied on electrodes placed on the surface of the skin to measure muscle activity, but those measurements have not proven reliable enough to ensure safety while walking with a neuroprosthetic leg. MIT researchers have now shown that tiny magnetic beads implanted in the muscle can accurately track muscle movement, and the team hopes this more accurate magnetic tracking system will enable commercial development of such limbs.
Electrode measurements fall short
“For four decades, the standard methodology for neurally controlling prostheses has been to use skin electrodes to measure muscle activation,” said Hugh Herr, a professor of media arts and sciences and co-director of the K. Lisa Yang Center for Bionics at MIT, and the senior author of the new study. Controlling a prosthetic limb requires controlling joint position, torque, or impedance, and such mechanical signals cannot be directly determined from electrical activation alone. Measurements of a muscle’s length, velocity and activation feed the control algorithms that guide the limbs, allowing people with leg amputation to walk with a more natural gait. The study appears in Nature Sensors, where three participants with below-knee amputations demonstrated the accuracy of the magnetic measurements. Lead authors include Christopher Shallal, an MIT graduate student in the Harvard-MIT Program in Health Sciences and Technology, and Cameron Taylor, an assistant professor of biomedical engineering at the University of North Carolina at Chapel Hill.
Paired magnets sense distance changes
The surface-electrode approach, known as electromyography, does not always provide accurate enough information. The electrical signal is not a perfect proxy for muscle dynamics and fades when a muscle is held at a fixed length for several seconds; electrodes may also pick up signals from muscles other than the intended target, and sweat can interfere with detection. The team’s method, known as magnetomicrometry, implants pairs of magnets into the muscles. When a muscle contracts or stretches, external sensors worn on the skin measure the change in distance between the magnets, allowing muscle length and velocity to be calculated. Shallal said magnets can be tracked wirelessly through the body, so placing two beads in the muscle gives access to rich information about muscle dynamics in a minimally invasive way. Last year, the lab reported a “bionic knee” prosthesis driven by electrodes implanted in the muscles; the magnetic approach relies on less invasive implants.
Three-way comparison in below-knee amputees
The new study extends the technique, first demonstrated in animal models in 2021, to humans with long-term magnetic implants. All three participants had a type of amputation that creates an agonist-antagonist myoneural interface (AMI), in which muscle pairs are reconnected during surgery so they still dynamically communicate with each other within the residual limb. This sensory feedback, called proprioception, helps the wearer decide how to position and move the prosthetic limb. Participants had magnets implanted in up to four muscles of the ankle joint, in surgeries performed at Brigham and Women’s Hospital with plastic surgeon Matthew Carty. The beads are 3 millimeters in diameter and made of a neodymium, iron and boron alloy, coated with gold and a polymer called parylene C to make them biocompatible. Their signals can be read from a depth of up to 6 centimeters beneath the skin, using a customized external sensor worn over the muscles being tracked.
Each participant also had electrodes implanted into the same muscles that received the magnetic beads, allowing the researchers to compare three types of measurements: magnetomicrometry, electromyography with implanted electrodes, and electromyography with electrodes on the surface of the skin. During the experiments, the participants were not wearing a prosthetic limb and used their muscle movements to move a cursor on a screen to particular targets. The same signals could in the future be fed into the controller of a robotic ankle-foot prosthesis. Shallal said the results suggest that the magnet-based approach can offer more accurate and stable control. The researchers are now performing a larger study evaluating how well people can control prosthetic limbs using measurements from the magnetic beads.
(Cover image is AI-generated, for illustrative purposes only)
Source: MIT News